- 1 Welcome to Vunetrix Network Monitor+
- 2 Quick Start Guide+
- 3 Installing the Software+
- 4 Understanding Basic Concepts+
- 5 Ajax Web Interface—Basic Procedures+
- 5.1 Login
- 5.2 SSL Certificate Warning
- 5.3 General Layout
- 5.4 Sensor States
- 5.5 Review Monitoring Data
- 5.6 Compare Sensors
- 5.7 Historic Data Reports
- 5.8 Similar Sensors
- 5.9 Object Settings
- 5.10 Alarms
- 5.11 Logs
- 5.12 Tickets
- 5.13 Working with Table Lists
- 5.14 Object Selector
- 5.15 Priority and Favorites
- 5.16 Pause
- 5.17 Context Menus
- 5.18 Hover Popup
- 5.19 Main Menu Structure
- 6 Ajax Web Interface—Device and Sensor Setup+
- 6.1 Auto-Discovery
- 6.2 Create Objects Manually+
- 6.3 Manage Device Tree
- 6.4 Root Group Settings
- 6.5 Probe Settings
- 6.6 Group Settings
- 6.7 Device Settings
- 6.8 Sensor Settings+
- 6.8.1 List of Available Sensor Types
- 6.8.2 Active Directory Replication Errors Sensor
- 6.8.3 ADO SQL Sensor
- 6.8.4 Amazon CloudWatch Sensor
- 6.8.5 AVM FRITZ!Box WAN Interface Sensor
- 6.8.6 Cisco IP SLA Sensor
- 6.8.7 Citrix XenServer Host Sensor
- 6.8.8 Citrix XenServer Virtual Machine Sensor
- 6.8.9 Cluster Probe Health Sensor
- 6.8.10 Core Health Sensor
- 6.8.11 Dell PowerVault MDi Sensor
- 6.8.12 DHCP Sensor
- 6.8.13 DNS Sensor
- 6.8.14 Enterprise Virtual Array Sensor
- 6.8.15 Event Log (Windows API) Sensor
- 6.8.16 Exchange Backup (Powershell) Sensor
- 6.8.17 Exchange Database (Powershell) Sensor
- 6.8.18 Exchange Mailbox (Powershell) Sensor
- 6.8.19 Exchange Mail Queue (Powershell) Sensor
- 6.8.20 Exchange Public Folder (Powershell) Sensor
- 6.8.21 EXE/Script Sensor
- 6.8.22 EXE/Script Advanced Sensor
- 6.8.23 File Sensor
- 6.8.24 File Content Sensor
- 6.8.25 Folder Sensor
- 6.8.26 FTP Sensor
- 6.8.27 FTP Server File Count Sensor
- 6.8.28 Google Analytics Sensor
- 6.8.29 HTTP Sensor
- 6.8.30 HTTP Advanced Sensor
- 6.8.31 HTTP Apache ModStatus PerfStats Sensor
- 6.8.32 HTTP Apache ModStatus Totals Sensor
- 6.8.33 HTTP Content Sensor
- 6.8.34 HTTP Full Web Page Sensor
- 6.8.35 HTTP Push Count Sensor
- 6.8.36 HTTP Push Data Sensor
- 6.8.37 HTTP Push Data Advanced Sensor
- 6.8.38 HTTP SSL Certificate Expiry Sensor
- 6.8.39 HTTP Transaction Sensor
- 6.8.40 HTTP XML/REST Value Sensor
- 6.8.41 Hyper-V Cluster Shared Volume Disk Free Sensor
- 6.8.42 Hyper-V Host Server Sensor
- 6.8.43 Hyper-V Virtual Machine Sensor
- 6.8.44 Hyper-V Virtual Network Adapter Sensor
- 6.8.45 Hyper-V Virtual Storage Device Sensor
- 6.8.46 IMAP Sensor
- 6.8.47 INI File Content Check Sensor
- 6.8.48 IP on DNS Blacklist Sensor
- 6.8.49 IPFIX Sensor
- 6.8.50 IPFIX (Custom) Sensor
- 6.8.51 jFlow V5 Sensor
- 6.8.52 jFlow V5 (Custom) Sensor
- 6.8.53 LDAP Sensor
- 6.8.54 Microsoft SQL Sensor
- 6.8.55 MySQL Sensor
- 6.8.56 NetFlow V5 Sensor
- 6.8.57 NetFlow V5 (Custom) Sensor
- 6.8.58 NetFlow V9 Sensor
- 6.8.59 NetFlow V9 (Custom) Sensor
- 6.8.60 Oracle SQL Sensor
- 6.8.61 Packet Sniffer Sensor
- 6.8.62 Packet Sniffer (Custom) Sensor
- 6.8.63 Passive Application Performance Sensor
- 6.8.64 PerfCounter Custom Sensor
- 6.8.65 PerfCounter IIS Application Pool Sensor
- 6.8.66 Ping Sensor
- 6.8.67 Ping Jitter Sensor
- 6.8.68 Pingdom Sensor
- 6.8.69 POP3 Sensor
- 6.8.70 POP3 Email Count Sensor
- 6.8.71 Port Sensor
- 6.8.72 Port Range Sensor
- 6.8.73 Probe Health Sensor
- 6.8.74 QoS (Quality of Service) One Way Sensor
- 6.8.75 QoS (Quality of Service) Round Trip Sensor
- 6.8.76 RADIUS Sensor
- 6.8.77 RDP (Remote Desktop) Sensor
- 6.8.78 SCVMM Host Sensor
- 6.8.79 SCVMM Virtual Machine Sensor
- 6.8.80 Sensor Factory Sensor
- 6.8.81 sFlow Sensor
- 6.8.82 sFlow (Custom) Sensor
- 6.8.83 SFTP Secure File Transfer Protocol Sensor
- 6.8.84 Share Disk Free Sensor
- 6.8.85 SIP Options Ping Sensor
- 6.8.86 SMTP Sensor
- 6.8.87 SMTP&IMAP Round Trip Sensor
- 6.8.88 SMTP&POP3 Round Trip Sensor
- 6.8.89 SNMP APC Hardware Sensor
- 6.8.90 SNMP Cisco ADSL Sensor
- 6.8.91 SNMP Cisco ASA VPN Connections Sensor
- 6.8.92 SNMP Cisco ASA VPN Traffic Sensor
- 6.8.93 SNMP Cisco ASA VPN Users Sensor
- 6.8.94 SNMP Cisco CBQoS Sensor
- 6.8.95 SNMP Cisco System Health Sensor
- 6.8.96 SNMP Cisco UCS Chassis Sensor
- 6.8.97 SNMP Cisco UCS Physical Disk Sensor
- 6.8.98 SNMP Cisco UCS System Health Sensor
- 6.8.99 SNMP CPU Load Sensor
- 6.8.100 SNMP Custom Sensor
- 6.8.101 SNMP Custom String Sensor
- 6.8.102 SNMP Dell Hardware Sensor
- 6.8.103 SNMP Dell PowerEdge Physical Disk Sensor
- 6.8.104 SNMP Dell PowerEdge System Health Sensor
- 6.8.105 SNMP Disk Free Sensor
- 6.8.106 SNMP GSA System Health Sensor
- 6.8.107 SNMP Hardware Status Sensor
- 6.8.108 SNMP HP LaserJet Hardware Sensor
- 6.8.109 SNMP HP ProLiant Logical Disk Sensor
- 6.8.110 SNMP HP ProLiant Memory Controller Sensor
- 6.8.111 SNMP HP ProLiant Network Interface Sensor
- 6.8.112 SNMP HP ProLiant Physical Disk Sensor
- 6.8.113 SNMP HP ProLiant System Health Sensor
- 6.8.114 SNMP IBM System X Logical Disk Sensor
- 6.8.115 SNMP IBM System X Physical Disk Sensor
- 6.8.116 SNMP IBM System X Physical Memory Sensor
- 6.8.117 SNMP IBM System X System Health Sensor
- 6.8.118 SNMP interSeptor Pro Environment Sensor
- 6.8.119 SNMP LenovoEMC Physical Disk Sensor
- 6.8.120 SNMP LenovoEMC System Health Sensor
- 6.8.121 SNMP Library Sensor
- 6.8.122 SNMP Linux Disk Free Sensor
- 6.8.123 SNMP Linux Load Average Sensor
- 6.8.124 SNMP Linux Meminfo Sensor
- 6.8.125 SNMP Linux Physical Disk Sensor
- 6.8.126 SNMP Memory Sensor
- 6.8.127 SNMP NetApp Disk Free Sensor
- 6.8.128 SNMP NetApp Enclosure Sensor
- 6.8.129 SNMP NetApp I/O Sensor
- 6.8.130 SNMP NetApp License Sensor
- 6.8.131 SNMP NetApp Logical Unit Sensor
- 6.8.132 SNMP NetApp Network Interface Sensor
- 6.8.133 SNMP NetApp System Health Sensor
- 6.8.134 SNMP Poseidon Environment Sensor
- 6.8.135 SNMP QNAP Logical Disk Sensor
- 6.8.136 SNMP QNAP Physical Disk Sensor
- 6.8.137 SNMP QNAP System Health Sensor
- 6.8.138 SNMP RMON Sensor
- 6.8.139 SNMP SonicWALL System Health Sensor
- 6.8.140 SNMP SonicWALL VPN Traffic Sensor
- 6.8.141 SNMP Synology Logical Disk Sensor
- 6.8.142 SNMP Synology Physical Disk Sensor
- 6.8.143 SNMP Synology System Health Sensor
- 6.8.144 SNMP System Uptime Sensor
- 6.8.145 SNMP Traffic Sensor
- 6.8.146 SNMP Trap Receiver Sensor
- 6.8.147 SNMP Windows Service Sensor
- 6.8.148 SNTP Sensor
- 6.8.149 SSH Disk Free Sensor
- 6.8.150 SSH INodes Free Sensor
- 6.8.151 SSH Load Average Sensor
- 6.8.152 SSH Meminfo Sensor
- 6.8.153 SSH Remote Ping Sensor
- 6.8.154 SSH SAN Logical Disk Sensor
- 6.8.155 SSH SAN Physical Disk Sensor
- 6.8.156 SSH SAN System Health Sensor
- 6.8.157 SSH Script Sensor
- 6.8.158 SSH Script Advanced Sensor
- 6.8.159 SSH VMWare ESX(i) Disk Sensor
- 6.8.160 Syslog Receiver Sensor
- 6.8.161 System Health Sensor
- 6.8.162 TFTP Sensor
- 6.8.163 Traceroute Hop Count Sensor
- 6.8.164 Virtuozzo Container Disk Sensor
- 6.8.165 Virtuozzo Container Network Sensor
- 6.8.166 VMware Host Hardware (WBEM) Sensor
- 6.8.167 VMware Host Hardware Status (SOAP) Sensor
- 6.8.168 VMware Host Performance (SOAP) Sensor
- 6.8.169 VMware Virtual Machine (SOAP) Sensor
- 6.8.170 WBEM Custom Sensor
- 6.8.171 Windows CPU Load Sensor
- 6.8.172 Windows IIS 6.0 SMTP Received Sensor
- 6.8.173 Windows IIS 6.0 SMTP Sent Sensor
- 6.8.174 Windows IIS Application Sensor
- 6.8.175 Windows Last Update Sensor
- 6.8.176 Windows Logged In Users Sensor
- 6.8.177 Windows MSMQ Queue Length Sensor
- 6.8.178 Windows Network Card Sensor
- 6.8.179 Windows Pagefile Sensor
- 6.8.180 Windows Physical Disk Sensor
- 6.8.181 Windows Print Queue Sensor
- 6.8.182 Windows Registry Sensor
- 6.8.183 Windows Scheduled Task Sensor
- 6.8.184 Windows System Uptime Sensor
- 6.8.185 Windows Updates Status (Powershell) Sensor
- 6.8.186 WMI Custom Sensor
- 6.8.187 WMI Custom String Sensor
- 6.8.188 WMI Event Log Sensor
- 6.8.189 WMI Exchange Server Sensor
- 6.8.190 WMI Exchange Transport Queue Sensor
- 6.8.191 WMI File Sensor
- 6.8.192 WMI Free Disk Space (Multi Drive) Sensor
- 6.8.193 WMI HDD Health Sensor
- 6.8.194 WMI Logical Disk Sensor
- 6.8.195 WMI Memory Sensor
- 6.8.196 WMI Microsoft SQL Server 2005 Sensor (Deprecated)
- 6.8.197 WMI Microsoft SQL Server 2008 Sensor
- 6.8.198 WMI Microsoft SQL Server 2012 Sensor
- 6.8.199 WMI Process Sensor
- 6.8.200 WMI Remote Ping Sensor
- 6.8.201 WMI Security Center Sensor
- 6.8.202 WMI Service Sensor
- 6.8.203 WMI Share Sensor
- 6.8.204 WMI SharePoint Process Sensor
- 6.8.205 WMI Terminal Services (Windows 2008) Sensor
- 6.8.206 WMI Terminal Services (Windows XP/Vista/2003) Sensor
- 6.8.207 WMI UTC Time Sensor
- 6.8.208 WMI Vital System Data (V2) Sensor
- 6.8.209 WMI Volume Sensor
- 6.8.210 WMI Volume Fragmentation Sensor
- 6.8.211 WMI Windows Version Sensor
- 6.8.212 WSUS Statistics Sensor
- 6.9 Additional Sensor Types (Custom Sensors)
- 6.10 Sensor Channels Settings
- 6.11 Sensor Notifications Settings
- 7 Ajax Web Interface—Advanced Procedures+
- 7.1 Toplists
- 7.2 Arrange Objects
- 7.3 Clone Object
- 7.4 Multi-Edit
- 7.5 Create Device Template
- 7.6 Geo Maps
- 7.7 Notifications+
- 7.8 Libraries+
- 7.9 Reports+
- 7.10 Maps+
- 7.11 Setup+
- 7.11.1 Account Settings—My Account
- 7.11.2 Account Settings—Notifications
- 7.11.3 Account Settings—Schedules
- 7.11.4 System Administration—User Interface
- 7.11.5 System Administration—Monitoring
- 7.11.6 System Administration—Notification Delivery
- 7.11.7 System Administration—Core & Probes
- 7.11.8 System Administration—User Accounts
- 7.11.9 System Administration—User Groups
- 7.11.10 System Administration—Administrative Tools
- 7.11.11 Vunetrix Status—System Status
- 7.11.12 Vunetrix Status—Auto-Update
- 7.11.13 Vunetrix Status—Activation Status
- 7.11.14 Optional Downloads and Add-Ons
- 7.11.15 Chrome Desktop Notifications
- 7.11.16 Support—Contact Support
- 8 Enterprise Console+
- 9 Other User Interfaces+
- 10 Sensor Technologies+
- 10.1 Monitoring via SNMP
- 10.2 Monitoring via WMI
- 10.3 Monitoring via SSH
- 10.4 Monitoring Bandwidth via Packet Sniffing
- 10.5 Monitoring Bandwidth via Flows
- 10.6 Bandwidth Monitoring Comparison
- 10.7 Monitoring Quality of Service and VoIP
- 10.8 Monitoring Email Round Trip
- 10.9 Monitoring Backups
- 10.10 Monitoring Virtual Environments
- 10.11 Monitoring Databases
- 10.12 Monitoring Syslogs and SNMP Traps
- 11 System Administration Tools+
- 12 Advanced Topics+
- 12.1 Active Directory Integration
- 12.2 Application Programming Interface (API) Definition
- 12.3 Filter Rules for xFlow, IPFIX and Packet Sniffer Sensors
- 12.4 Channel Definitions for xFlow, IPFIX, and Packet Sniffer Sensors
- 12.5 Define IP Ranges
- 12.6 Define Lookups
- 12.7 Regular Expressions
- 12.8 Add Remote Probe+
- 12.9 Data Storage
- 12.10 Using Your Own SSL Certificate with Vunetrix's Web Server
- 12.11 Calculating Percentiles
- 13 Appendix+
Vunetrix Manual: Monitoring via SNMP
Monitoring via Simple Network Management Protocol (SNMP) is the most basic method of gathering bandwidth and network usage data.
SNMP can be used to monitor bandwidth usage of routers and switches on a port-by-port basis, as well as device readings such as memory, CPU load, etc. The queried devices must support SNMP.
Network Monitoring via SNMP
When this technology is used, Vunetrix sends small data packets to devices, for example, querying routers, switches, and servers for the traffic counters of each port. These are triggering reply packets from the device. Compared to Vunetrix's other bandwidth monitoring techologies via flows, packet sniffing, or WMI, the SNMP option creates the least CPU and network load.
Reasons to Choose SNMP Monitoring
SNMP is the most commonly used method mainly because it is easy to set up and requires minimal bandwidth and CPU cycles. If your network devices support SNMP and/or if you want to monitor large networks with several hundred or thousands of sensors, we recommend you start with SNMP. Besides network usage monitoring, another well-known feature of SNMP is the ability to also watch other network parameters such as CPU load, disk usage, temperature, as well monitoring many other readings, depending on the queried device.
In order to use Simple Network Management Protocol (SNMP) for monitoring purposes, it is imperative that UDP packets are allowed to travel from the machine running Vunetrix to the device you want to monitor and back, which is usually the case in LANs and Intranets. For connections across the internet, to a Demilitarized Zone (DMZ), or for Wide Area Network (WAN) connections, some changes to the traversed firewalls may be necessary. Keep in mind that SNMP V1 and V2c are not secure protocols and should not be used across the internet or insecure data connections. Only SNMP version 3 supports encryption.
To better understand and set up SNMP sensors, you may want to learn more about the principle of Object Identifiers (OID) and Management Information Base (MIB). For more information about this, please refer to the Knowledge Base article in the More section below.
For an overview and details about all SNMP sensors, please see the List of Available Sensor Types section.
Vunetrix supports three versions of the SNMP protocol: Version 1, version 2c, and version 3.
SNMP Version 1
This is the oldest and most basic version of SNMP.
- Pro: Supported by most SNMP-compatible devices; simple to set up.
- Contra: Limited security as it only uses a simple password (community string) and data is sent in clear text (unencrypted). It should therefore only be used inside LANs behind firewalls, not in WANs; only supports 32-bit counters which is not enough for high-load (gigabits/second) bandwidth monitoring.
SNMP Version 2c
This version adds 64-bit counters.
- Pro: Supports 64-bit counters to monitor bandwidth usage in networks with gigabits/second loads.
- Contra: Limited security (same as with SNMP V1).
SNMP Version 3
This version adds authentication and encryption to SNMP.
- Pro: Offers user accounts and authentication for multiple users and optional data packet encryption, increasing available security; plus all advantages of Version 2c.
- Contra: Difficult to configure. Not suitable for large networks (see below for more information).
It is important to know that if you select an SNMP version which is not supported by the server or device you want to monitor, you will receive an error message. Unfortunately, in most cases, these error messages do not explicitly mention the possibility that you could be using the incorrect SNMP version. These messages provide minimum information only, such as cannot connect or similar. Similar error occur when community strings, usernames, or passwords don't match.
SNMP Overload and Limitations of the SNMP System
SNMP V1 and V2 scale directly with the performance of the hardware and the speed of the network. In our labs we were able to monitor 30,000 SNMP V1 sensors at a 60 second interval with one Vunetrix server (core and local probe) plus two remote probes with 10,000 sensors each.
However, SNMP V3 has performance limitations due to the SSL encryption. The main limiting factor is CPU power (as well as the other general limits for Vunetrix). Because of this limitation, you can monitor only a limited number of sensors per second using SNMP V3. Currently, Vunetrix is able to handle roughly 40 requests per second and computer core, depending on your system. This means that, on a common 1.x GHz computer with two cores, you can run about 5,000 SNMP v3 sensors with a 60 seconds scanning interval; on a system with four cores, you can monitor around 10,000 sensors with 60 seconds interval. The CPU load is at about 50% then. We do not recommend more.
Furthermore, the Vunetrix core server and probes should run on different computers. If you experience increased values in the Interval Delay SNMP or Open Requests channels of the Probe Health sensor (values above 0 % indicate that the SNMP requests cannot be performed at the desired interval), you need to distribute the load over multiple probes. SNMP V1 and V2 do not have this limitation.
If you run into SNMP overload problems you have three options:
- Increase the monitoring interval of the SNMP V3 sensors.
- Distribute the SNMP V3 sensors over two or more probes.
- Switch to SNMP V1 or V2 if you can go without encryption.
What is the SNMP Community String?
The SNMP Community String is similar to a user ID or password that allows access to a router's or other device's statistics. Vunetrix Network Monitor sends the community string along with all SNMP requests. If the correct community string is provided, the device responds with the requested information. If the community string is incorrect, the device simply discards the request and does not respond.
Note: SNMP community strings are only used by devices that support SNMP V1 and SNMP V2c protocols. SNMP V3 uses safer username/password authentication, along with an encryption key.
By convention, most SNMP V1/V2c equipment ships with a read-only community string set to the value public. It is standard practice for network managers to change all the community strings to customized values during device setup.
If you run into troubles with SNMP Overload or have questions about scaling your Vunetrix system to avoid such troubles, please contact Vunetrix Technical Support.
Keywords: SNMP,SNMP Technology