- 1 Welcome to Vunetrix Network Monitor+
- 2 Quick Start Guide+
- 3 Installing the Software+
- 4 Understanding Basic Concepts+
- 5 Ajax Web Interface—Basic Procedures+
- 5.1 Login
- 5.2 SSL Certificate Warning
- 5.3 General Layout
- 5.4 Sensor States
- 5.5 Review Monitoring Data
- 5.6 Compare Sensors
- 5.7 Historic Data Reports
- 5.8 Similar Sensors
- 5.9 Object Settings
- 5.10 Alarms
- 5.11 Logs
- 5.12 Tickets
- 5.13 Working with Table Lists
- 5.14 Object Selector
- 5.15 Priority and Favorites
- 5.16 Pause
- 5.17 Context Menus
- 5.18 Hover Popup
- 5.19 Main Menu Structure
- 6 Ajax Web Interface—Device and Sensor Setup+
- 6.1 Auto-Discovery
- 6.2 Create Objects Manually+
- 6.3 Manage Device Tree
- 6.4 Root Group Settings
- 6.5 Probe Settings
- 6.6 Group Settings
- 6.7 Device Settings
- 6.8 Sensor Settings+
- 6.8.1 List of Available Sensor Types
- 6.8.2 Active Directory Replication Errors Sensor
- 6.8.3 ADO SQL Sensor
- 6.8.4 Amazon CloudWatch Sensor
- 6.8.5 AVM FRITZ!Box WAN Interface Sensor
- 6.8.6 Cisco IP SLA Sensor
- 6.8.7 Citrix XenServer Host Sensor
- 6.8.8 Citrix XenServer Virtual Machine Sensor
- 6.8.9 Cluster Probe Health Sensor
- 6.8.10 Core Health Sensor
- 6.8.11 Dell PowerVault MDi Sensor
- 6.8.12 DHCP Sensor
- 6.8.13 DNS Sensor
- 6.8.14 Enterprise Virtual Array Sensor
- 6.8.15 Event Log (Windows API) Sensor
- 6.8.16 Exchange Backup (Powershell) Sensor
- 6.8.17 Exchange Database (Powershell) Sensor
- 6.8.18 Exchange Mailbox (Powershell) Sensor
- 6.8.19 Exchange Mail Queue (Powershell) Sensor
- 6.8.20 Exchange Public Folder (Powershell) Sensor
- 6.8.21 EXE/Script Sensor
- 6.8.22 EXE/Script Advanced Sensor
- 6.8.23 File Sensor
- 6.8.24 File Content Sensor
- 6.8.25 Folder Sensor
- 6.8.26 FTP Sensor
- 6.8.27 FTP Server File Count Sensor
- 6.8.28 Google Analytics Sensor
- 6.8.29 HTTP Sensor
- 6.8.30 HTTP Advanced Sensor
- 6.8.31 HTTP Apache ModStatus PerfStats Sensor
- 6.8.32 HTTP Apache ModStatus Totals Sensor
- 6.8.33 HTTP Content Sensor
- 6.8.34 HTTP Full Web Page Sensor
- 6.8.35 HTTP Push Count Sensor
- 6.8.36 HTTP Push Data Sensor
- 6.8.37 HTTP Push Data Advanced Sensor
- 6.8.38 HTTP SSL Certificate Expiry Sensor
- 6.8.39 HTTP Transaction Sensor
- 6.8.40 HTTP XML/REST Value Sensor
- 6.8.41 Hyper-V Cluster Shared Volume Disk Free Sensor
- 6.8.42 Hyper-V Host Server Sensor
- 6.8.43 Hyper-V Virtual Machine Sensor
- 6.8.44 Hyper-V Virtual Network Adapter Sensor
- 6.8.45 Hyper-V Virtual Storage Device Sensor
- 6.8.46 IMAP Sensor
- 6.8.47 INI File Content Check Sensor
- 6.8.48 IP on DNS Blacklist Sensor
- 6.8.49 IPFIX Sensor
- 6.8.50 IPFIX (Custom) Sensor
- 6.8.51 jFlow V5 Sensor
- 6.8.52 jFlow V5 (Custom) Sensor
- 6.8.53 LDAP Sensor
- 6.8.54 Microsoft SQL Sensor
- 6.8.55 MySQL Sensor
- 6.8.56 NetFlow V5 Sensor
- 6.8.57 NetFlow V5 (Custom) Sensor
- 6.8.58 NetFlow V9 Sensor
- 6.8.59 NetFlow V9 (Custom) Sensor
- 6.8.60 Oracle SQL Sensor
- 6.8.61 Packet Sniffer Sensor
- 6.8.62 Packet Sniffer (Custom) Sensor
- 6.8.63 Passive Application Performance Sensor
- 6.8.64 PerfCounter Custom Sensor
- 6.8.65 PerfCounter IIS Application Pool Sensor
- 6.8.66 Ping Sensor
- 6.8.67 Ping Jitter Sensor
- 6.8.68 Pingdom Sensor
- 6.8.69 POP3 Sensor
- 6.8.70 POP3 Email Count Sensor
- 6.8.71 Port Sensor
- 6.8.72 Port Range Sensor
- 6.8.73 Probe Health Sensor
- 6.8.74 QoS (Quality of Service) One Way Sensor
- 6.8.75 QoS (Quality of Service) Round Trip Sensor
- 6.8.76 RADIUS Sensor
- 6.8.77 RDP (Remote Desktop) Sensor
- 6.8.78 SCVMM Host Sensor
- 6.8.79 SCVMM Virtual Machine Sensor
- 6.8.80 Sensor Factory Sensor
- 6.8.81 sFlow Sensor
- 6.8.82 sFlow (Custom) Sensor
- 6.8.83 SFTP Secure File Transfer Protocol Sensor
- 6.8.84 Share Disk Free Sensor
- 6.8.85 SIP Options Ping Sensor
- 6.8.86 SMTP Sensor
- 6.8.87 SMTP&IMAP Round Trip Sensor
- 6.8.88 SMTP&POP3 Round Trip Sensor
- 6.8.89 SNMP APC Hardware Sensor
- 6.8.90 SNMP Cisco ADSL Sensor
- 6.8.91 SNMP Cisco ASA VPN Connections Sensor
- 6.8.92 SNMP Cisco ASA VPN Traffic Sensor
- 6.8.93 SNMP Cisco ASA VPN Users Sensor
- 6.8.94 SNMP Cisco CBQoS Sensor
- 6.8.95 SNMP Cisco System Health Sensor
- 6.8.96 SNMP Cisco UCS Chassis Sensor
- 6.8.97 SNMP Cisco UCS Physical Disk Sensor
- 6.8.98 SNMP Cisco UCS System Health Sensor
- 6.8.99 SNMP CPU Load Sensor
- 6.8.100 SNMP Custom Sensor
- 6.8.101 SNMP Custom String Sensor
- 6.8.102 SNMP Dell Hardware Sensor
- 6.8.103 SNMP Dell PowerEdge Physical Disk Sensor
- 6.8.104 SNMP Dell PowerEdge System Health Sensor
- 6.8.105 SNMP Disk Free Sensor
- 6.8.106 SNMP GSA System Health Sensor
- 6.8.107 SNMP Hardware Status Sensor
- 6.8.108 SNMP HP LaserJet Hardware Sensor
- 6.8.109 SNMP HP ProLiant Logical Disk Sensor
- 6.8.110 SNMP HP ProLiant Memory Controller Sensor
- 6.8.111 SNMP HP ProLiant Network Interface Sensor
- 6.8.112 SNMP HP ProLiant Physical Disk Sensor
- 6.8.113 SNMP HP ProLiant System Health Sensor
- 6.8.114 SNMP IBM System X Logical Disk Sensor
- 6.8.115 SNMP IBM System X Physical Disk Sensor
- 6.8.116 SNMP IBM System X Physical Memory Sensor
- 6.8.117 SNMP IBM System X System Health Sensor
- 6.8.118 SNMP interSeptor Pro Environment Sensor
- 6.8.119 SNMP LenovoEMC Physical Disk Sensor
- 6.8.120 SNMP LenovoEMC System Health Sensor
- 6.8.121 SNMP Library Sensor
- 6.8.122 SNMP Linux Disk Free Sensor
- 6.8.123 SNMP Linux Load Average Sensor
- 6.8.124 SNMP Linux Meminfo Sensor
- 6.8.125 SNMP Linux Physical Disk Sensor
- 6.8.126 SNMP Memory Sensor
- 6.8.127 SNMP NetApp Disk Free Sensor
- 6.8.128 SNMP NetApp Enclosure Sensor
- 6.8.129 SNMP NetApp I/O Sensor
- 6.8.130 SNMP NetApp License Sensor
- 6.8.131 SNMP NetApp Logical Unit Sensor
- 6.8.132 SNMP NetApp Network Interface Sensor
- 6.8.133 SNMP NetApp System Health Sensor
- 6.8.134 SNMP Poseidon Environment Sensor
- 6.8.135 SNMP QNAP Logical Disk Sensor
- 6.8.136 SNMP QNAP Physical Disk Sensor
- 6.8.137 SNMP QNAP System Health Sensor
- 6.8.138 SNMP RMON Sensor
- 6.8.139 SNMP SonicWALL System Health Sensor
- 6.8.140 SNMP SonicWALL VPN Traffic Sensor
- 6.8.141 SNMP Synology Logical Disk Sensor
- 6.8.142 SNMP Synology Physical Disk Sensor
- 6.8.143 SNMP Synology System Health Sensor
- 6.8.144 SNMP System Uptime Sensor
- 6.8.145 SNMP Traffic Sensor
- 6.8.146 SNMP Trap Receiver Sensor
- 6.8.147 SNMP Windows Service Sensor
- 6.8.148 SNTP Sensor
- 6.8.149 SSH Disk Free Sensor
- 6.8.150 SSH INodes Free Sensor
- 6.8.151 SSH Load Average Sensor
- 6.8.152 SSH Meminfo Sensor
- 6.8.153 SSH Remote Ping Sensor
- 6.8.154 SSH SAN Logical Disk Sensor
- 6.8.155 SSH SAN Physical Disk Sensor
- 6.8.156 SSH SAN System Health Sensor
- 6.8.157 SSH Script Sensor
- 6.8.158 SSH Script Advanced Sensor
- 6.8.159 SSH VMWare ESX(i) Disk Sensor
- 6.8.160 Syslog Receiver Sensor
- 6.8.161 System Health Sensor
- 6.8.162 TFTP Sensor
- 6.8.163 Traceroute Hop Count Sensor
- 6.8.164 Virtuozzo Container Disk Sensor
- 6.8.165 Virtuozzo Container Network Sensor
- 6.8.166 VMware Host Hardware (WBEM) Sensor
- 6.8.167 VMware Host Hardware Status (SOAP) Sensor
- 6.8.168 VMware Host Performance (SOAP) Sensor
- 6.8.169 VMware Virtual Machine (SOAP) Sensor
- 6.8.170 WBEM Custom Sensor
- 6.8.171 Windows CPU Load Sensor
- 6.8.172 Windows IIS 6.0 SMTP Received Sensor
- 6.8.173 Windows IIS 6.0 SMTP Sent Sensor
- 6.8.174 Windows IIS Application Sensor
- 6.8.175 Windows Last Update Sensor
- 6.8.176 Windows Logged In Users Sensor
- 6.8.177 Windows MSMQ Queue Length Sensor
- 6.8.178 Windows Network Card Sensor
- 6.8.179 Windows Pagefile Sensor
- 6.8.180 Windows Physical Disk Sensor
- 6.8.181 Windows Print Queue Sensor
- 6.8.182 Windows Registry Sensor
- 6.8.183 Windows Scheduled Task Sensor
- 6.8.184 Windows System Uptime Sensor
- 6.8.185 Windows Updates Status (Powershell) Sensor
- 6.8.186 WMI Custom Sensor
- 6.8.187 WMI Custom String Sensor
- 6.8.188 WMI Event Log Sensor
- 6.8.189 WMI Exchange Server Sensor
- 6.8.190 WMI Exchange Transport Queue Sensor
- 6.8.191 WMI File Sensor
- 6.8.192 WMI Free Disk Space (Multi Drive) Sensor
- 6.8.193 WMI HDD Health Sensor
- 6.8.194 WMI Logical Disk Sensor
- 6.8.195 WMI Memory Sensor
- 6.8.196 WMI Microsoft SQL Server 2005 Sensor (Deprecated)
- 6.8.197 WMI Microsoft SQL Server 2008 Sensor
- 6.8.198 WMI Microsoft SQL Server 2012 Sensor
- 6.8.199 WMI Process Sensor
- 6.8.200 WMI Remote Ping Sensor
- 6.8.201 WMI Security Center Sensor
- 6.8.202 WMI Service Sensor
- 6.8.203 WMI Share Sensor
- 6.8.204 WMI SharePoint Process Sensor
- 6.8.205 WMI Terminal Services (Windows 2008) Sensor
- 6.8.206 WMI Terminal Services (Windows XP/Vista/2003) Sensor
- 6.8.207 WMI UTC Time Sensor
- 6.8.208 WMI Vital System Data (V2) Sensor
- 6.8.209 WMI Volume Sensor
- 6.8.210 WMI Volume Fragmentation Sensor
- 6.8.211 WMI Windows Version Sensor
- 6.8.212 WSUS Statistics Sensor
- 6.9 Additional Sensor Types (Custom Sensors)
- 6.10 Sensor Channels Settings
- 6.11 Sensor Notifications Settings
- 7 Ajax Web Interface—Advanced Procedures+
- 7.1 Toplists
- 7.2 Arrange Objects
- 7.3 Clone Object
- 7.4 Multi-Edit
- 7.5 Create Device Template
- 7.6 Geo Maps
- 7.7 Notifications+
- 7.8 Libraries+
- 7.9 Reports+
- 7.10 Maps+
- 7.11 Setup+
- 7.11.1 Account Settings—My Account
- 7.11.2 Account Settings—Notifications
- 7.11.3 Account Settings—Schedules
- 7.11.4 System Administration—User Interface
- 7.11.5 System Administration—Monitoring
- 7.11.6 System Administration—Notification Delivery
- 7.11.7 System Administration—Core & Probes
- 7.11.8 System Administration—User Accounts
- 7.11.9 System Administration—User Groups
- 7.11.10 System Administration—Administrative Tools
- 7.11.11 Vunetrix Status—System Status
- 7.11.12 Vunetrix Status—Auto-Update
- 7.11.13 Vunetrix Status—Activation Status
- 7.11.14 Optional Downloads and Add-Ons
- 7.11.15 Chrome Desktop Notifications
- 7.11.16 Support—Contact Support
- 8 Enterprise Console+
- 9 Other User Interfaces+
- 10 Sensor Technologies+
- 10.1 Monitoring via SNMP
- 10.2 Monitoring via WMI
- 10.3 Monitoring via SSH
- 10.4 Monitoring Bandwidth via Packet Sniffing
- 10.5 Monitoring Bandwidth via Flows
- 10.6 Bandwidth Monitoring Comparison
- 10.7 Monitoring Quality of Service and VoIP
- 10.8 Monitoring Email Round Trip
- 10.9 Monitoring Backups
- 10.10 Monitoring Virtual Environments
- 10.11 Monitoring Databases
- 10.12 Monitoring Syslogs and SNMP Traps
- 11 System Administration Tools+
- 12 Advanced Topics+
- 12.1 Active Directory Integration
- 12.2 Application Programming Interface (API) Definition
- 12.3 Filter Rules for xFlow, IPFIX and Packet Sniffer Sensors
- 12.4 Channel Definitions for xFlow, IPFIX, and Packet Sniffer Sensors
- 12.5 Define IP Ranges
- 12.6 Define Lookups
- 12.7 Regular Expressions
- 12.8 Add Remote Probe+
- 12.9 Data Storage
- 12.10 Using Your Own SSL Certificate with Vunetrix's Web Server
- 12.11 Calculating Percentiles
- 13 Appendix+
Vunetrix Manual: Monitoring Quality of Service and VoIP
Vunetrix can monitor the Quality of Service in a network with dedicated QoS sensors, as well as Cisco IP Service Level Agreement (SLA) and Cisco Class Based Quality of Service (CBQoS). Slight variations of network parameters like jitter, packet loss, or packet delay variation (PDV) usually have only little effect on TCP based services (e.g. HTTP, SMTP, etc.). But for UDP based services like Voice over IP (VoIP) and video streaming a steady stream of data packets is crucial. The sound quality of a VoIP call drops dramatically when UDP packets are not received in a timely fashion, or if packets are lost or out-of-order. As a rule of thumb for good quality of service (in a VoIP perspective) you would want low measurements for jitter (less than 20 to 50 ms) and PDV (less than 100 ms) and preferably zero measurements for packet loss, duplicated packets, or packets in wrong order.
For Quality of Service measurements, four sensors are available:
- QoS (Quality of Service) Sensor
Monitors VoIP relevant network parameters by testing network connection quality between two probes. - QoS (Quality of Service) Round Trip Sensor
Monitors VoIP relevant network parameters by testing network connection quality between two probes. Traffic is measured bidirectional. - Cisco IP SLA Sensor
Monitors VoIP relevant network parameters through IP SLA results from Cisco devices (via SNMP). - SNMP Cisco CBQoS Sensor
Monitors VoIP relevant network parameters by using Cisco's CBQoS (via SNMP).
QoS (Quality of Service) Sensor
The QoS Sensor is used to monitor the quality of a network connection by measuring the following parameters:
- Jitter in ms according to RFC 3550
- Packet delay variation (PDV) in ms according to RFC 3393
- Lost packets in %
- Out-of-order packets in %
- Duplicated packets in %
The measurements are taken by sending UDP packets between two probes. This means that you can test any network connection in your network by simply placing a remote probe on (or near) each 'end' of the connection and measuring the connection quality between them. This is the perfect tool to find network issues that can affect VoIP sound quality or video streaming 'hiccups'.
Monitoring Quality of Service with Vunetrix
As mentioned before, measurements are taken between two probes. So the first step is to place two PCs running a remote probe on (or near) both ends of the connection that you want to monitor. As an alternative, the local probe on the PC running the Vunetrix core can also be used as one end. If any firewalls, packet filters or Network Address Translation (NAT) systems are en route, you must configure them as necessary so that the UDP packets can reach the target probe.
In Vunetrix, create a new QoS sensor on a Probe Device. Please find details about settings in the QoS (Quality of Service) Sensor section. With the settings for number and for size of the packets you can configure the test data stream. 1,000 packets of 172 bytes each is a good start, but if your applications use larger packets you may want to enter other values here. Try to configure the test streams with parameters similar to that of the UDP services you are using across this connection.
Wikipedia describes IP SLA as a feature included in the Cisco IOS Software that can allow administrators the ability to Analyze IP Service Levels for IP applications and services. IP SLA uses active traffic-monitoring technology to monitor continuous traffic on the network. This is a reliable method in measuring over head network performance. IP-SLA is mostly used to monitor the sound quality of VoIP traffic.
If you haven't done so already, please add a device in Vunetrix for the Cisco device that you want to monitor. Then create a new Cisco IP SLA sensor on this device. Please find details about settings in the Cisco IP SLA Sensor section.
This feature is only available in the more expensive Cisco devices. If you don't have IP SLA capable routers/switches you can still get similar information with Vunetrix's QoS sensor (see above) which does not require any special hardware—just two PCs running Windows. If you do own hardware which supports IP SLA then Vunetrix brings you probably the least-cost monitoring solution for IP SLA. Most vendors charge extra for IP SLA support (a thousand bucks and more). Following Paessler's long term policy we simply include this as one of our sensor types. With Vunetrix you can even use the Freeware Edition to monitor IP SLA!
Vunetrix monitors the following parameters: Calculated Planning Impairment Factor (ICPIF), Mean Opinion Score (MOS), Average Jitter, Packets Lost, Packets Out Of Sequence, Packets Late, Average Round Trip Time (RTT), DNS RTT, TCP RTT, Transaction RTT. Especially two of these parameters are interesting for VoIP: Mean Opinion Score (MOS) and Calculated Planning Impairment Factor (ICPIF).
Cisco Class Based Quality of Service (CBQoS) provides information about QoS of Cisco network devices which support the Modular QoS command line interface (MQC). With Classed Based QoS, you can obtain monitoring data that includes summary counts and rates by traffic class before and after the enforcement of QoS policies, according to Cisco's CBQoS Management Information Base (MIB) definition. Vunetrix determines CBQoS data via Simple Network Management Protocol (SNMP). The corresponding sensor type is available out-of-the-box in Vunetrix version 13.x.5 or later. CBQoS is available in Cisco IOS by default as of version 12.4(4)T.
In order to monitor CBQoS, add a device to Vunetrix for the Cisco device that you want to monitor. Then create a new SNMP Cisco CBQoS sensor on this device. Please see section SNMP Cisco CBQoS Sensor for more details.
This sensor type supports the following CBQoS classes:
- Class Map: statistical data about class maps, such as pre- and post-policy packets and sizes, drop packets and size, as well as no-buffer drop packets
- Match Statement: statistical data about match statement specific information, such as pre-policy packets and size
- Queueing: statistical data about queuing actions, such as current and maximum queue depth, drop packets, and drop size
You can select the desired CBQoS entries which you want to monitor while creating the sensor in Vunetrix. The available entries are given with their particular connections, their descriptions, and class types.
For Mean Opinion Score (MOS) measurements, Cisco conducted a panel test where a wide range of listeners judged the quality of voice samples sent using particular codecs, on a scale of 1 (poor quality) to 5 (excellent quality). The Cisco device calculated the corresponding value for the current network connection based on the network parameter measurements like jitter and packet loss. The values and their meanings are:
MOS |
Quality |
Expected Quality Impairment |
5 |
Excellent |
Imperceptible |
4 |
Good |
Perceptible, but not annoying |
3 |
Fair |
Slightly annoying |
2 |
Poor |
Annoying |
1 |
Bad |
Very annoying |
The second interesting parameter ICPIF is the sum of measured impairment factors minus a user-defined access Advantage Factor that is intended to represent the user's expectations, based on how the call was placed (for example, a mobile call versus a land-line call) (quoted from Cisco's website).
Upper Limit for ICPIF |
VoIP Call Communication Quality |
5 |
Very good |
10 |
Good |
20 |
Adequate |
30 |
Limiting case |
45 |
Exceptional limiting case |
55 |
Customers likely to react strongly (complaints, change of network operator) |